86
Fault code
on the dis-
play
System characteris-
tics
Cause Measures
10 Controls as if the out-
side temperature
were 0 °C
Short circuit, out-
side temperature
sensor
Check the outside tem-
perature sensor (see
page 95)
18 Controls as if the out-
side temperature
were 0 °C
Lead break, out-
side temperature
sensor
Check the outside tem-
perature sensor (see
page 95)
20 Regulates without
flow temperature
sensor (low loss
header)
Short circuit, sys-
tem flow tempera-
ture sensor
Check the low loss header
sensor (see page 96)
28 Regulates without
flow temperature
sensor (low loss
header)
Lead break, sys-
tem flow tempera-
ture sensor
Check the low loss header
sensor (see page 96)
30 Burner blocked Short circuit, boiler
water temperature
sensor
Check the boiler water
temperature sensor (see
page 96)
38 Burner blocked Lead break, boiler
water temperature
sensor
Check the boiler water
temperature sensor (see
page 96)
40 Mixer closes Short circuit, flow
temperature sen-
sor, heating circuit
2 (with mixer)
Check flow temperature
sensor
48 Mixer closes Lead break, flow
temperature sen-
sor, heating circuit
2 (with mixer)
Check flow temperature
sensor
50 No DHW heating Short circuit, cylin-
der temperature
sensor
Check sensors (see
page 96)
51 No DHW heating Short circuit, outlet
temperature sen-
sor
Check sensors (see
page 96)
58 No DHW heating Lead break, cylin-
der temperature
sensor
Check sensors (see
page 96)
Troubleshooting
Fault codes
5418 193 GB