29
Enter names for heating circuits: Operating instructions
Checking the gas type
The boiler is equipped with an electronic combustion control unit that adjusts the
burner for optimum combustion in accordance with the prevailing gas quality.
■ Consequently, for natural gas there is no adjustment required across the entire
Wobbe range.
The boiler can be operated in the Wobbe index range 9.5 to 15.2 kWh/m
3
(34.2 to
54.7 MJ/m
3
).
■ Convert the burner for operation with LPG (see "Gas type conversion" on
page 30).
1. Determine the gas type and Wobbe
index by asking your local gas supply
utility or LPG supplier.
2. Convert the burner for operation with
LPG (see page 30).
3. Record the gas type in the service
report on page 135.