5693 976 - 04
Vitotronic 200 and 300-K Installation and Service
Installation Sequence
Overview of Electrical Connections, Vitotronic 300-K
Electrical connections on the Vitotronic 200
see installation instructions, Vitodens 200-W.
Legend
PCB, extension for heating circuits 2 and 3 (accessory)
? M2/M3 Supply temperature sensor
M2/M3 Heating circuit pump
gS M2/M3 Mixing valve motor
Main circuit board, low voltage
! Outside temperature sensor
§/? Common supply/ low loss header,
temperature sensor
%A DHW tank temperature sensor
%B DHW tank temperature sensor 2 for primary
store system (accessory)
aJB Temperature sensor primary store system
(accessories)
aVD External hook-ups
aVG KM BUS participant (Vitotronic 200 and
accessories, e.g. Vitotrol remote controls)
aVH External hook-ups
LON LON BUS, connecting cable for data exchange
with the
Vitotronic 200-H and the
Vitocom
Main PCB 120V~
A1 Heating circuit pump
or
Primary pump, primary store system
sA DHW pump
sK DHW recirculation pump
sL System pump
Power supply
Central fault message
gSA1 Motor for 3-way mixing valve, primary store
system
aBH Internal power supply for mixing valve extension
PCB
With
accessory
module