133
Dis-
played
fault
code
Const. Weath.-
comp.
System char-
acteristics
Cause Measures
Fd X X Burner in a fault
state and addi-
tional fault b7 is
displayed
Coding card
missing
Insert coding card.
Press reset button
R.
Replace control
unit if fault per-
sists.
Fd X X Burner in a fault
state
Fault, burner
control unit
Check ignition
electrodes and
connecting cables.
Check whether a
strong interference
(EMC) field exists
near the appliance.
Press reset button
R.
Replace control
unit if fault per-
sists.
FE X X Burner blocked
or in a fault
state
Coding card
or main PCB
faulty, or in-
correct cod-
ing card
Press reset button
R. If the fault per-
sists, check the
coding card and re-
place coding card
or control unit if
necessary.
FF X X Burner blocked
or in a fault
state
Internal fault
or reset but-
ton R
blocked
Restart the appli-
ance. Replace the
control unit if the
appliance will not
restart.
Troubleshooting