Coding
Coding in the delivered condition Possible change
Set DHW temperature reheating suppression
67:40 For solar DHW heating:
Set DHW temperature
40 °C. Reheating is sup-
pressed above the selec-
ted set temperature (boil-
er is only connected as
backup if the rise in cylin-
der temperature is too
low).
Cannot be adjusted on
combi boilers.
67:0
to
67:95
Set DHW temperature ad-
justable from 0 to 95 °C
(limited by boiler-specific
parameters)
Enable DHW circulation pump
73:0 DHW circulation pump:
"ON" according to time
program (only for weath-
er-compensated control
units and system boilers)
73:1
to
73:6
"ON" from once per hour
for 5 min up to
6 times per hour for 5 min
during the time program
73:7 Constantly "ON"
"Solar"/group 4
Select "Solar" for weather-compensa-
ted control units (see page 60).
Select "4" for constant temperature con-
trol units (see page 60).
Note
The solar group is only displayed if a
solar control module, type SM1, is con-
nected.
Coding
Coding in the delivered condition Possible change
Speed control solar circuit pump
02:0 Solar circuit pump is not
speed-controlled.
02:1 Solar circuit pump is
speed-controlled with
wave packet control.
02:2 Solar circuit pump is
speed-controlled with
PWM control.
Code 1
"DHW"/group 3
(cont.)
5772 909 GB
Service