223
Plug Terminals Function Explanation
sYS
212.1 AC function control
"active cooling"
■ Max. output: 10 W
■ Voltage: 230 V~
Create circuit on site
212.2 Heating circuit pump
for heating circuit with-
out mixer (A1)
■ This pump is installed in addition
to the secondary pump if a heat-
ing water buffer cylinder is instal-
led.
■ Max. output: 100 W
Connect on site
212.3 DHW circulation pump ■ Max. output: 50 W
■ Voltage: 230 V~
Connect on site
sXÖ
220.1
220.2
Compressor control
stage 2 (type BWS) via
EEV controller (refrig-
erant circuit control)
■ Heat demand: Contact closed,
220.2 is 'live'
■ If the compressor will not start,
check whether it has been ena-
bled by the EEV controller stage
2 (own relay on EEV PCB stage
2)
Factory connection
sXS
222.1 Mixer motor control for
external heat source
Signal Mixer CLOSED
■ Voltage: 230 V~
Connect on site
222.2 Mixer motor control for
external heat source
Signal Mixer OPEN
■ Voltage: 230 V~
Connect on site
222.3
222.4
External heat source
control
Zero volt contact:
■ Contact load 230 V/50 Hz,
4(2) A
Connect on site
sXD
223.1
223.2
Central fault message Zero volt contact:
■ Closed: Fault
■ Open: No fault
■ Contact load 230 V/50 Hz,
4(2) A
■ Not suitable for safety LV
Connect on site
Connection and wiring diagrams
Overview of the PCBs and connection options
(cont.)
5442 829 GB