Service menu:
1. Press OK + å simultaneously for
approx. 4 s.
2. "Coding level 1"
3. "Heating circuit 1"
or
"Heating circuit 2"
or
"Heating circuit 3"
or
"Separate cooling circuit"
4. Select parameter.
Note
The parameters in the parameter groups
Heating circuit 1, Heating circuit 2 and
Heating circuit 3 are identical.
The assignment to the heating circuit is
determined by the first digit of the param-
eter code:
2xxx for heating circuit 1
3xxx for heating circuit 2
4xxx for heating circuit 3
2000/2001/2022 Room temperatures and switching times
"Standard room temperature 2000"
"Reduced room temperature 2001"
"Party temperature 2022"
Adjusting the set room temperatures and
time programmes for all heating circuits
(A1, M2 and M3).
Operating instructions
"Standard room tempera-
ture 2000"
"Party temperature 2022"
"Reduced room tempera-
ture 2001"
Delivered condition
200 ( 20 °C) 160 ( 16 °C)
Setting range 100 to 300
(
10 to 30 °C)
100 to 300
(
10 to 30 °C)
2003 Enabling the remote control
"Remote control 2003"
Parameter group heating circuits/cooling circuit
Parameter group heating circuits
5442 829 GB
Service