4 Starting up / Operation
4.1 Initial start-up
The initial start-up is carried out either by KÖB
Holzfeuerungen GmbH or another heating special-
ist.
Be absolutely sure to follow the instructions in
the Assembly and Installation Instructions. No
guarantee may be claimed in cases of initial
start-ups carried out improperly by oneself.
First check:
- Is there enough water in the heating system?
- Has the heating system been bled?
- Are the slide valves open to the heating forward
and reverse flow?
- Can enough fresh air get into the heating
room?
- Are the doors and lids on the burner all closed
leak-tight?
4.2 Starting up
Check the storage unit temperature!
Check
whether the storage unit temperature has dropped
so far that heating up is practical, and whether the
amount of heat to be expected can be accepted or
stored.
Maximum storage unit temperature: 90°C
4.2.1 Filling
CAUTION: Never fill shavings or woodchips di-
rectly from the grate Æ There is a danger such
going up in flames suddenly!
- The slots in the grate have to be free of ash.
Only charcoal (approx. 2 cm) may remain lying
on the grate. Evenly spread out paper on this
(better than cardboard) and easily combustible
wood over the entire width of the burner
(approx. 25 cm high). Position the pieces of
wood crosswise such that a layer permeable to
air is created.
Finer material may only be filled on the layer of
chopped wood.
- Neatly lay the billet wood and logs horizontally
and compactly over the entire width of the fire-
box.
- Only refill as much wood as energy that the
storage unit can still accommodate until the
maximum storage unit temperature of 90°C is
reached.
- When closing the access door, be sure that
the supporting surface for the refill access lid
seal is clean.
Note that even a small ember remaining can
also inadvertently ignite the kindling wood.
4.2.2 Heating up
Kindling
- Is the airway (1) to (3) clear through the entire
area of the grate, through fuel at the bottom and
into the combustion chamber? Is the lower part
of the wood loaded (2) permeable to air?
- Open the ash pan lid. Ignite, ideally doing so
over the entire width of the firebox,
- such that the fire spreads over the entire area
of the grate as quickly as possible.
Aim to keep the heating-up procedure short,
quickly producing a lot of heat and embers.
Rapid heating up of the combustion chamber
rapidly produces perfect incineration.
- Press the F1 button "PYROMAT Wood".
- Leave the ash pan lid approx. 10 cm open until
the material to be burned has started to burn
well.
- When the temperature of the exhaust gas
reaches approx. 110°C, close the ash pan lid.