12
Initial start-up
Further details regarding individual steps (cont.)
Adjusting system settings
At the setting level (see below), the following parameters and functions can
be adjusted:
Temperatures
Differential temperatures DO/DF
. . . . . . . . . . .
Maximum cylinder temperatureĂ SX. . .
¨ Observe the max. permissible
DHW temperature.
Collector limit temperatureĂ
ĂCL. . . . . . . . . . . .
Maximum collector temperatureĂ ĂCX
Minimum collector temperatureĂ
ĂCN.
Functions
Max. cylinder temperature control
Collector cooling function
Reverse cooling
Special functions
Further parameters
For recording the heat volume
H Volume flow
H Heat transfer medium
Calling up the setting level
The control unit is equipped with a display and a setting level.
1. Select HO with "+".
2. Press "+" for approx. 3Ăseconds;
SE
will be displayed.
3. Select the required parameter with
"+" or "ć" (see above); confirm
with "OK";
SE
flashes.
4. Select the required value with "+"
or "ć"; confirm with "OK".
Please note:
After approx. 2Ăminutes, the
display reverts to the standard
screen (showing the collector and
DHW cylinder temperature) if no
confirmation of modified values
is received or other settings are
changed.
For detailed explanations, see chapter on system details/functions.