Viessmann VITOCELL 300-H Service Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
Connections
16
Steam Heating Side Connections only for 92 and 120 USG / 350 and 450 ltr capacity
Do not use Vitocell indirect-fired hot water storage tanks in superheated steam
applications.
Use appropriate control strategy.
Control strategy must ensure that the values below are not exceeded.
Install a st eam-side control to regulate DHW temperature and ensure that the DHW
temperature does not exceed 210°F / 99°C.
H Maximum working pressure on heat
exchanger side up to 220 psig at
392°F / 200°C or a steam pres s ure of
15 psig at 250°F / 121°C
H Maximum working pressure on DHW
water side of up to 150 psig at
210°F / 99°C
Individual DHW tank
Vitocell 300
Sensor/Aquastat well
Vacuum breaker
Steam valve
Steam supply line
Condensation return line
Condensate trap
1. Pipe steam and condensate lines as
illustrated. Connections must be
accessible f or service (use factory
supplied adaptors).
Use hemp and pipe dope on all threaded
stainless steel nipples on tank.
2. Remove plastic grommets on tank
where condensate lines connect
(grommets are left threaded).
3. Install DHW tank temperature sensor
in sensor well; install steam valve.
Installation Instructions
Control Valve
4. Insulate piping.
5167 535 v1.3
Domestic hot water temperatures
over 125°F / 52°C can cause severe
burns instantly or death from scalds.
Children, disabled and elderly are at
highest risk of being s calded.
Feel water before bathing or
showering.
Temperature limiting valves are
available and must be used where
domestic hot water storage tank
temperatures exceed 140°F / 60°C.
DANGER
The operating aquastat and any
secondary high limit aquastat of the
tank must be set such that the DHW
temperature inside the tank never
exceeds 210°F / 99°C.
WARNING
Fig 10.
Recommended piping of an individual tank in a steam system
IMPORTANT
For steam applications, a field
supplied 1” T&P valve must be
utilized.
CAUTION